ApexEgroup LLC
Direct Line:
1-330-476-2422
Quotes@ApexScales.com
Bench Scales Balance Scales Price Computing Scales Floor Scales Onboard Mining Scales Drum Scales Vulcan Scales Washdown Scales
Crane Scales Platform Scales Laboratory Scales Forklift Scales Onboard Scales Logging Scales Doran Scales Wireless Scales
Batching Scales Stainless Steel Scales Washdown Bench Scales Mechanical Scales Truck Axle Scales Skidsteer Scales Intercomp Scales Weigh in Motion Scales
Control Systems Shipping Scales Load Cells & Printers Medical Scales Small Plane Scales Wheel Loader Scales Precisa Scales Wheel Weigher Scales
SI Road Runner Platform Aircraft Scale Systems Refuse Trucks Scales Tipping Body Scales Dump Trucks Scales SI Scales Roll-off Truck Scales
Because of the nature of our business, Our suppliers will remain operational as an Essential Service throughout the corona virus shutdowns.
LIMITED TIME ONLY: 4% DISCOUNT & GROUND SHIPPING IF PAID BY CHECK FOR MOST ITEMS
.
Signal Conditioning Transmitter Indicators

SCT-1100 Advanced Series Signal Conditioning Weight Transmitter

The ideal solution for PLC systems which require weight data from a scale, Rice Lake’s SCT signal transmitters offer maximum control without the additional cost or space required of a traditional weight indicator.

These multi-function transmitters have a compact design while presenting the same signal-conditioning functions.

Utilized as an independent or dependent four-channel digital junction box, the SCT-1100 allows for the direct reading and diagnosis of each individual connected load cell or summed as a whole.
  • Up to four independent scales or four load cell inputs
  • Quick menu for real and theoretical calibration
  • Red LED display (13mm) and six LEDs show active functions
  • Standard DIN rail-mounting with power supply and enclosures
  • Configurable calibration and setup parameters from keyboard
  • Up to three calibration linearization points or three from the keyboard
  • Reading of the net, gross and tare weights, clearing, semi-automatic and presettable tare, scale switch, setting of outputs application thresholds
  • Diagnostic information via serial port, message display, printing, setting of APW in counting mode, simulation of key pressure
Total Control in a Compact Package The ideal solution for PLC systems which require weight data from a scale, Rice Lake’s SCT signal transmitters offer maximum control without the additional cost or space required of a traditional weight indicator. These multi-function transmitters have a compact design while presenting the same signal-conditioning functions as a traditional weight indicator. Utilized as an independent or dependent four-channel digital junction box, the SCT-1100 allows for the direct reading and diagnosis of each individual connected load cell or summed as a whole. The ability to be DIN rail-mounted within a cabinet or control panel, permits a straightforward implementation into new and existing systems. Integration is also made simple with a wide range of available fieldbus communications, as well as optional Bluetooth® , Wi-Fi and radio interfaces for external management.
SCT-1100 Advanced Series Signal Conditioning Weight Transmitter
Power:
12/24 VDC
Power Consumption:
70 mA min – 100 mA max
Excitation Voltage:
5VDC, 120 mA, 8 x 350 Ω Load Cells
Analog Signal Input Range:
± 39 mV
Analog Signal Sensitivity:
0.03 µV/graduation minimum
0.3 µV/graduation recommended
A/D Sample Rate:
Four channel A/D 24-bit sigma-delta conversion, up to 200 conv. /sec. auto select
Resolution:
Internal resolution: 1.5 million counts
Weight display resolution: 800,000
Digital Inputs/Outputs:
Two inputs: 12/24 VDC
Two outputs:150 mA 48 VAC/ 150 mA 60 VDC 
Serial Port:
1-RS-485, 1-RS-232
Analog Output (if equipped):
Opt isolated, 16-bit
0-20mA, 4-20mA (Maximum 350 ohm)
0-5VDC, 0-10VDC (Minimum 10,000 ohm)
Display:
Six-digit (13 mm), red LED
Annunciators: 
Net, center of zero, stability
Keyboard:
Five key, membrane panel, tactile feel
Zero (Down), Tare (Up), Mode (Right), Print (Enter), C (On/Off)
Temperature & Humidity:
Working temperature: 5° F to 104° F (-15° C to 40° C) 
Humidity: 85% non-condensing
Dimensions (W x H x D):
4.17 in x 3.54 in x 2.28 in (106 mm x 90 mm x 58 mm)
Weight:
1 lb (0.5 kg)
Rating/Material:
NEMA Type 1 plastic pluggable connectors
Warranty:
One-year limited warranty
Model SCT1100 Description SCT Transmitters Price
RL-SCT1100-AN-182588 Indicator,SCT1100-AN 12-24VDC and, RS485/RS232 Serial Port, Analog Out DIN Mount, 4 load cell input $ 385.00
Model Description Convert Serial to Ethernet Price
RL-SCT-1000-188483 SCT-1000 Converts RS-232/RS485 output to RJ45 Ethernet TCP/IP and Modbus TCP $ 375.00
Model Power Supplies Description Price
RL-DIN Rail-Power supply-88792 Power Supply, IDEC 12VDC DIN Rail Mount, 1.3 Amp, Input: 85 to 264 VAC, 100 to 370 VDC 15W $130.00
RL-DIN Rail-Power supply-119244 24VDC 1.3A DIN rail mounted power supply $ 150.00

 

SCT-2200 Advanced Series Signal Conditioning Weight Transmitter

Maximum Control, Miniature Size

For PLC systems that require weight data from a scale, Rice Lake’s compact SCT transmitters deliver equivalent signal-conditioning function without the cost or bulk of a full size weight indicator/controller.
  • HUB Mode connects up to 16 transmitters to one fieldbus
  • Quick menu for real and theoretical calibration
  • Web browser weight monitoring and calibration over EtherNet/IP, Profinet and Modbus TCP network
  • Red LED display with six-digits (8 mm) and six LEDs show active functions
  • Standard DIN rail-mounting with power supply and enclosures
  • Configurable calibration and setup parameters from keyboard
  • Up to three calibration linearization points or three from the keyboard
  • Reading of the net, gross and tare weights, clearing, semi-automatic and presettable tare, scale switch, setting of outputs application thresholds
  • Diagnostic information via serial port, message display, printing, setting of APW in counting mode, simulation of key pressure, Modbus RTU
  • Double RS-485 port for a quick network connection
  • Printer management on second serial port available
  • Multi-range function allows for subdividing the scale capacity in two, each up to 3,000 divisions
Optional Fieldbus
  • Profinet
  • Ethernet TCP/IP
  • Wi-Fi Ethernet
  • Profibus
  • EtherNet/IP
  • DeviceNet
  • EtherCAT
  • CANopen
Power:
12/24 VDC
Power Consumption:
70 mA min – 100 mA max
Excitation Voltage:
5VDC, 120 mA, up to 8 x 350 Ω Load Cells
Analog Signal Input Range:
± 39 mV
Analog Signal Sensitivity:
0.03 µV/graduation minimum
0.3 µV/graduation recommended
A/D Sample Rate:
One channel A/D 24-bit sigma-delta conversion, up to 200 conv. /sec. auto select
Resolution:
Internal resolution: 1.5 million counts
Weight display resolution: 800,000
Digital Inputs/Outputs:
Two inputs: 12/24 VDC
Two outputs:150 mA 48 VAC/ 150 mA 60 VDC
Serial Port:
1-RS-485, 1-RS-232
Analog Output (if equipped):
Opt isolated, 16-bit
0-20mA, 4-20mA (Maximum 350 ohm)
0-5VDC, 0-10VDC (Minimum 10,000 ohm)
Display:
Six-digit  0.31 in(8 mm), red LED
Annunciators:
Net, center of zero, stability
Keyboard:
Five key, tactile feel
Zero (Down), Tare (Up), Mode (Right), Print (Enter), C (On/Off)
Temperature & Humidity:
Working Temperature: 14° F to 122° F (-10° C to 50° C) 
Humidity: 85% non-condensing
Dimensions (W x H x D):
0.98 in x 4.52 in x 4.72 in 
(25 mm x 115 mm x 120 mm)
Weight:
1 lb (0.5 kg)
Rating/Material:
NEMA Type 1 plastic pluggable connectors
Warranty:
One-year limited warranty
 
SCT-2200 as a Single input port for load cells.
Single Load cell Hoppers, Bench scale applications
Four cells from a Hoppers, Floor scale application etc.
Max Load: 5VDC, 120 mA, up to 8 x 350 Ω Load Cells
How to order the SCT-2200
1. Order SCT-220 Transmitter
2. Order Fieldbus module (HUB mode connects up to 16 transmitters to one Fieldbus module)
3. Order Cables - RJ45 - RS485 Connection Cable for Fieldbus
Model Transmitters Description SCT Transmitters Price
RL-SCT-2200-182587 Indicator,SCT2200 12-24VDC,and RS485/232 Serial Port, DIN Mount $ 270.00
RL-SCT-2200AN-182589 Indicator,SCT2200-AN Analog Output, 12-24VDC, and RS485/232 Serial Port DIN Mount $ 385.00
Model Fieldbus Description Fieldbus Price
RL-SCT-2200-Fieldbus-Profinet-182592 Fieldbus,SCT2200, Profinet 12-24VDC, RS485 Connection and ProfiNet output DIN Mount $ 470.00
RL-SCT-2200-Fieldbus-WIFI-182595
Fieldbus, SCT2200, WIFI 12-24VDC, RS485 Connection and WiFi and TCP/IP Output DIN Mount $ 460.00
RL-SCT-2200-Fieldbus-Profibus-182593 Fieldbus,SCT2200, Profibus 12-24VDC, RS485 Connection and Profibus output DIN Mount $ 300.00
RL-SCT-2200-Fieldbus- E/IP-182591 Fieldbus, SCT2200, E/IP 12-24VDC, RS485 Connection and Ethernet/IP output DIN Mount $ 470.00
RL-SCT-2200-Fieldbus-Dev.Net-182596 Fieldbus,SCT2200, Dev.Net 12-24VDC, RS485 Connection and DeviceNet output DIN Mount $ 470.00
RL-SCT-2200-Fieldbus-Ethercat-182597 Fieldbus,SCT2200, Ethercat 12-24VDC, RS485 Connection and Ethercat output DIN Mount $ 470.00
RL-SCT-2200-Fieldbus-CANOPEN-182599 Fieldbus,SCT2200, CANOPEN 12-24VDC, RS485 Connection and CANOPEN output DIN Mount $ 470.00
RL-SCT-2200-Fieldbus-Connection Cable for Fieldbus-182599 Cable, SCT2200 RS485 Connection Cable for Fieldbus, (6")150mm long, w/RJ45 $ 10.00
RL-SCT-2200-Fieldbus- Module -188483 Fieldbus,SCT-1000 Module 12-24VDC, RS232/485 Connection for Ethernet TCP/IP or MODBUS TCP DIN Mount $ 375.00
Model SCT1100 Description SCT Transmitters Price
RL-SCT1100-AN-182588 Indicator,SCT1100-AN 12-24VDC and, RS485/RS232 Serial Port, Analog Out DIN Mount, 4 load cell input $ 385.00
Model Description Convert Serial to Ethernet Price
RL-SCT-1000-188483 SCT-1000 Converts RS-232/RS485 output to RJ45 Ethernet TCP/IP and Modbus TCP $ 375.00
Model Power Supplies Description Price
RL-DIN Rail-Power supply-88792 Power Supply, IDEC 12VDC DIN Rail Mount, 1.3 Amp, Input: 85 to 264 VAC, 100 to 370 VDC 15W $130.00
RL-DIN Rail-Power supply-119244 24VDC 1.3A DIN rail mounted power supply $ 150.00

 

Fieldbus Configuration Files Size Download PDF - Zip File
CANopen EDS File for SCT-2200 21.03 KB
Download
DeviceNet EDS File for SCT-2200 744 B
Download
EtherCAT ESI File for SCT-2200 14.77 KB
Download
EtherNet/IP EDS File for SCT-2200 5.54 KB
Download
Profibus GSD File for SCT-2200 1.49 KB
Download
Profinet GSDML File for SCT-2200 2.86 KB
Download
Software Files Size Download PDF - Zip File
Rice Lake Tools V-4.22.00 58.08 MB
Download
Single Scale Sample Program for Allen-Bradley PLC 268.15 KB
Download

Six Scale Hub Mode Sample Program for Allen-Bradley PLC

1.8 MB
Download

 

What is:
Fieldbus: is the name of a family of industrial computer network protocols used for real-time distributed control, standardized as IEC 61158. A complex automated industrial system — such as manufacturing assembly line — usually needs a distributed control system—an organized hierarchy of controller systems—to function.
PROFIBUS: (Process Field Bus) is a standard for fieldbus communication in automation technology and was first promoted in 1989 by BMBF (German department of education and research) and then used by Siemens. It should not be confused with the PROFINET standard for Industrial Ethernet.
Modbus: is a serial communications protocol originally published by Modicon (now Schneider Electric) in 1979 for use with its programmable logic controllers (PLCs). Modbus has become a de facto standard communication protocol and is now a commonly available means of connecting industrial electronic devices.
DeviceNet: is a network protocol used in the automation industry to interconnect control devices for data exchange. It utilizes the Common Industrial Protocol over a Controller Area Network media layer and defines an application layer to cover a range of device profiles.
EtherCAT: (Ethernet for Control Automation Technology) is an Ethernet-based fieldbus system, invented by Beckhoff Automation. The protocol is standardized in IEC 61158 and is suitable for both hard and soft real-time computing requirements in automation technology.
CANopen: is a communication protocol and device profile specification for embedded systems used in automation. In terms of the OSI model, CANopen implements the layers above and including the network layer.
EtherNet/IP: (IP = Industrial Protocol) is an industrial network protocol that adapts the Common Industrial Protocol to standard Ethernet.
TCP: (Transmission Control Protocol) is a standard that defines how to establish and maintain a network conversation through which application programs can exchange data. TCP works with the Internet Protocol (IP), which defines how computers send packets of data to each other.
Analog Output: An analog control output signal is used when a device needs to function at more than two points in a range. A common output range for an analog signal is 0-10 volts (other analog signals used commonly are 2-10V, 4-20mA and 0-20mA). A digital control output signal allows a device to operate at only two points.
Load Cells Parallel: Load cells can be connected in parallel; in that case, all the corresponding signals are connected together (Ex+ to Ex+, S+ to S+, ...), and the resulting signal is the average of the signals from all the sensing elements. This is often used in e.g. personal scales, or other multipoint weight sensors.

 

 

 

Product Menu

ApexScales.com
ApexEgroup LLC Direct Line - 1-330-476-2422
We record all calls for quality assurance.
CopyRight © 1987-Present Date
No Customer Data Stored on our Servers
Installable Systems/Parts/Made or Configured to order: Are NON-Refundable
Celebrating 33 years of Service in the Scale Industry.
ApexEgroupLLC@gmail.com
Quotes@ApexScales.com
Note: Because the nature of our business our products are in-line with the manufacturer's policies and are non-refundable. Scales, Installable Systems, Electronic Parts, Made to order, Configured systems are non-refundable.
Some manufacture's & states require's us to pay your State Sales Tax.
Most of our manufacture's (RLWS, SI, Vulcan Scales, VPG) has a presence in the states listed below. These States will not honor our tax certificate.
We try to cover the tax if we can. Purchase of mutiple system all tax and shipping are normally covered.
RLWS Taxable States:

California, Florida, Illinois, Maryland, Pennsylvania, Indiana, Louisiana, Massachusetts, Mississippi, New York, Virginia, West Virginia, Wyoming

SI Scales & Vulcan Scales, VPG taxable States:
CALIFORNIA, CONNECTICUT, GEORGIA, ILLINOIS, KANSAS, MARYLAND, MASSACHUSETTS, MICHIGAN, MINNESOTA, OHIO, PENNSYLVANIA, SOUTH CAROLINA, TEXAS, WASHINGTON.